A high frequency 120 kHz, Anatomically Programmed Radiography (APR) generator with LCD display and an advanced microprocessor control design. A reliable and technologically advanced generator that is flexible to the preferences of the technologist.
High-frequency X-Ray
Model : ANTHEM
Manufacturer: Del Medical
Origin : USA
Composition
1. X-RAY GENERATOR:
Model: ANTHEM
Manufacturer: Del Medical, Inc - USA
Origin : USA
Features
10 - 15 minute calibration
Integrated 24 volt AC.DC power supply
Integrated line match transformer
Update APR by SD card or PC
Up to 640 Anatomical Programs with over 10,000 techniques.
Programmed techniques for 8 body regions and up to 12 views per region
Two point operation provides individual control of kV and mAs
Three point operation provides individual control of mA, kV and time
Optional AEC operation can be used in all modes
Continuous kV and mA stabilization
Automatic line voltage compensation
Tube protection software and circuitry
Pedestal stand included
Compact design minimizes space requirements
Maximum mA:650
kW Rating: 30 - 50
kVp Range: 40 - 125
Two Point Operation: mAs Range: 1.0 - 600
Three Point Operation: 15 mA Stations 25S/50S/75S/100S/100L/150L/200L/250L/300L/350L/400L/450L/500L/550L/600L/650L
2.FOUR-WAY FLOAT TOP MEDICAL X-RAY TABLE
Model: RT 100
Manufacturer: Del Medical, Inc - USA
Origin : USA
Features
17” x 17” image receptor with heavy-duty manual tray
Heavy-duty electric table locks with foot treadle release
All steel structure and welded base provides maximum strength and reliability
Smooth, stain resistant composite fiber resin top
Pedestal base can house generator electronics to save space
Table base length: 43 in. (109 cm)
Table base width: 29 in. (74 cm)
Table top length: 86.62 in. (2.2 meters)
Table top width: 32 in. (81 cm)
Table top height: 33 in. (84 cm)
Longitudinal travel: 54.50 in. (138 cm)
Transverse travel: 9.80 in. (25 cm)
Table top-to-film distance: 3.25 in. (8 cm)
Bucky travel: Longitudinal 11.4 in. (29 cm) ; Allows for 65 in. (165 cm) of complete longitudinal radiographic coverage
Power Requirements: 120 VAC or 230-240 VAC
3. VERTICAL WALL STAND:
Model: VS100 / 3546E
Manufacturer: Del Medical, Inc - USA
Origin : USA
A counterbalanced wall stand with vertical electric locks that allow for easy positioning. The extensive vertical travel allows for a complete range of exams from skull to weight bearing knee and ankle exams.
Dual counterweight cables for added safety
Vertical travel range of 62.60” (159cm)
Available with 17” x 17” (43cm x 43cm) grid cabinet or bucky and a wide slection of grid options
Wall stand height: 86.75” (220.4cm)
Receptor height: 23.38” (59.4cm)
Vertical travel range: 62.60” (159cm)
Wall stand width (with receptor): 23.25” (59cm)
Wall stand depth (with receptor): 13” (33cm)
Maximum focal spot height: 74” (188cm)
Minimum focal spot height: 11.40” (29cm)
Front panel aluminum equivalency: 0.4mm
Weight: 258lb (117kg)
Power requirements: 24VDC
4. Tube Stand:
Model: FWFC
Manufacturer: Del Medical, Inc - USA
Origin : USA
The Del Medical Non-Rotate Tube Stand offers versatility and ease of handing for general radiography.
The FWFC Tube Stand is designed to facilitate the wide range of procedures common to hospitals, ambulatory care centers and group practice facilities. And affordable price and short payback period easily satisfy budget concerns.
The sturdy tube-mount assembly permits precise x-ray field alignment and stability.
Electromagnetic vertical and longitudinal locks are some of the standard features that add operator convenience and rapid patient positioning.
Electromagnetic locks provide maximum holding power and control key directional movements of tube angulation around the horizontal axis provides alignment of tube to image receptor. Control buttons for the longitudinal and vertical locks.
Longitudinal Travel: 72” (183 cm)
Vertical Travel: Min. 9.75” (25 cm), Max. 74.5” (189 cm)
Tube rotation around horizontal axis: ± 180º, with 0º, ± 90º detents
Longitudinal Rails: 8’
Power Requirements: 120 VAC or 230 / 240 VAC
5. Rotating Anode X-Ray Tube:
Model: E7239FX
Manufacturer: Toshiba - Japan
Origin: USA
Rotating anode X-ray tube housing assembly for the purpose of general diagnostic X-ray procedures.
Specially processed Rhenium-tungsten faced molybdenum target of 74 mm diameter.
These tubes have foci 2.0 mm and 1.0 mm, and are available for a maximum tube voltage 125 kV with Three-phase generator.
Accommodated with IEC 60526 type high-voltage cable receptacles.
Focal Spot:
Large Focus : 2.0 mm
Small Focus : 1.0 mm
6. Manual Collimator
Model: R221/A DHHS
Manufacturer: Ralco Srl. - Italia
Origin: USA
Multilayer, square field, manual collimation system with a lightweight and compact design intended for installation on mobile and stationary X-ray equipment. This device has been designed and manufactured for skeletal investigations and ER applications.
The X-ray field is defined by six pairs of shutters, four of which are lead-lined. The six pairs of shutters move perpendicularly within the X-ray field. Two pairs of brass shutters are located near the focus, two are located near the entrance window and two are located near the exit window of the X-ray beam from the collimator. The latter shutters serve to accurately define the X-ray field edges.
Shutter movements are manual, controlled by two knobs on the collimator front panel.
Power Supply 24 V AC/ DC - 50/60 Hz - 6.5 A
Inherent Filtration Al. Equivalent EN 60601-1-3 par. 7.3; 7.4 : Min. Al 2 mm (1 mm on request) at 75 kV
Limitation of Extra Focal Radiation Set Focus Distance, SID 1 m (EN 60601-2-54) : < 150 mm Square X-ray Field Selection 100 cm (40") SID - (± 1% SID) (EN 60601-2-54) : Min: 00 x 00 cm , Max: 48 x 48 cm Light Field Indicator - Contrast : > 4:1
Edge Contrast Setting 35x35 cm at 1 m SID (EN 60601-2-54)
Light Field Indicator Precision < 1 % SID>
Precision of Measurement with Retractable Tape (EN 60601-2-54) : < 2% SID
Maximum Radiation Leakage Measured at 100 cm with X-ray Beam = 150 kVp - 4 mA (EN 60601-2-54) : < 40 mR