The BASIC 100-30 unit uses a X-ray generator with double focus rotating anode X-Ray Tube Head, which allows to effect a wide range of exams.
The X-ray generator’s inverter, thanks to the high operating frequency and to the optimum efficiency, shows an almost continuous output voltage (ripple ≤ 3% at the maximum power).
The X-ray unit, thanks to a capacitors bank for energy storage, can be connected to every standard 230 Vac supply mains, even where the line resistance is not the best(≤ 2,5 Ω).
The highly ergonomic LCD Touch Screen control panel offers excellent supervision of all parameters and possible regulations.
Moreover, the microprocessor control unit provides ease of use (topped by the possibility of saving up to 1200 pre-programmed anatomical techniques with an alphanumeric keyboard in the LCD Touch Screen) and high reliability.
Mobile X-ray
Model : Basic 100-30
Manufacturer : Intermedical S.r.l
Origin: Italia
Radiological Features
Small focus Large focus
Max Power 11 kW 32 kW
mA Range 50 ÷150 mA (Step of 5 mA) 100 ÷ 450 mA (Step of 5 mA)
Exposure Time 2,2 ms ÷ 4 s (Step of 1 ms) 1,1 ms ÷ 2 s (Step of 1 ms)
Working Frequency 100 kHz 100 kHz
kV Range 40 ÷ 125 (Step of 1 kV) 40 ÷ 125 (Step of 1 kV)
mAs Range 0,2 ÷ 200 mAs in 26 values 0,5 ÷ 200 mAs in 25 values
H.V. Driving Inverter driven by IGBT Inverter driven by IGBT
Ripple ≤ 3% at Max Power ≤ 3% at Max Power
Total Filtration > 2,7 mmAl > 2,7 mmAl
kV Rising Time ≤ 1 ms ≤ 1 ms
X-Ray Tube
Anodic Rated Power(IEC 613, EN 60613) : 11kW small focus/32 kW large focus
Nominal Foci Size (IEC 336, EN 60336) : 0.6mm – 1.3 mm
Speed of Rotation : 2850rpm @ 50Hz – 3400rpm @ 60Hz
Anodic Diameter : 64mm
Anode Material : Tungsten
Anodic Angle : 15°
Tube Material : Glass
Inherent Filtration (IEC 522) @75kV : 0.7mmAl eq.
Thermal Anode Capacity : 80kJ (107kHU)
Max. Continuous Anode Dissipation : 375W (527HU/sec)
Max. Anode Cooling Rate : 22kJ/min (29.5kHU/min)
Nominal High Voltage :130kV
Max. Filament Current : 5.4A
Collimator
Type : Manual square fields with internal light source, and centering lines
Light Source : Halogen Lamp 12V 100W with temporized ignition at approx. 30s.
Fuse : 8A
Field Covering : From 0x0cm to 43x43cm at 1m DFF
Brightness Intensity : 160lux at 1m DFF
Contrast Ratio : 4:1
Measure of Focus-Film Distance : Extensible measure
Rotation : ± 90°
Max Protection Against Leaked Radiation : 125kV 4mA
Indicator Precision : Corresponds to X-ray fields with tolerance lower than 2% of used FFD.
Inherent Filtration @75kV : 2.0mmAl eq.
Brightness Field Precision : Corresponds to the X-ray field with tolerance lower than the 2% of used FFD.
Operating Modes and Functionality
User’s Interface Polycarbonate flat keyboard with graphic LCD touch screen display for all the operative parameters and messages of possible anomalous conditions – administrated by a microprocessor
Operating Modes in Radiography : Two-points technique (kV-mAs) , Three-points technique (kV-mA-ms) , 500 storable expositions with: patient data (name, surname, date of birth, address, sex, fiscal code), radiographical parameters (kV, mA, t, mAs, exposure date) and dose (in case of DAP option) , 200 programmable anatomical techniques for 6 patient’s typologies, for a total of 1200 programmable anatomical techniques
X-ray Control : Distance control with double click and extensible cable (≥4m)
Safety : Filament current , mAmin and mAmax , Maximum exposure time , Temperature maximum X-ray tube head , Count thermal units X-ray tube head , Max kV, min kV,, max ΔkV, max I , Anode rotation , Microprocessor self – test
Mechanical Features
Width 580 mm
Length 1360 mm
Height 1467 mm
Minimum Source-Floor Distance 382 mm
Maximum Source-Floor Distance 2012 mm
Max Range 1118 mm
Maximum Focal Height with 1000 mm Arm Extension 1845 mm
Pivoting Front Rubber Wheel Diameter Ø 75 mm
Maximum difference in level which can be overcome with tilting 55 mm
Pivoting Back Rubber Wheels Diameter Ø 150 mm
Weight 195 kg
Movement Manual
Cassette Holder 35x43 cm : 6